| Sign In | Join Free | My chinacomputerparts.com |
|
Brand Name : XG
Model Number : FN7
Certification : ISO,CCC
Place of Origin : XIAN,CHINA
MOQ : 1 SET
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 2000 SET
Delivery Time : 3-7 DAYS
Packaging Details : WOODEN CASE
Type : indoor
Rated Voltage : 7.2kV, 12kV
Rated Current : 400A 630A, 1250A, 1600A, 2000A, 2500A, 3150A,
Frequency : 50/60Hz
Poles Number : 3
Phase : 3 phase
Medium : vacuum
Material : galvanized sheet and accessories
24kv Three-pole Load Break Switch are designed according to a modular system, parting from a non-load isolator switch (refer to section Non-load isolating switches), whose galvanized steel frame has several drillings that allow the conversion of an isolator switch into a disconnecting switch without any problem, even when
already installed in the field, by simply adding the arcing chambers. This efficient design also allows the easy replace-ability of parts and maintenance.
2. data
| No. | Description | Unit | Data |
| 1 | Rated voltage (Un) | KV | 24 |
| 2 | Max.working voltage(Umax) | KV | 24 |
| 3 | Rated frequency | Hz | 50 |
| 4 | Rated current | A | 630 |
| 5 | Rated short time current 1 secretary(Ith) 3. secretary(Ith) | kA rms | 20 10 |
| 6 | Rated peak current (Idvn) | kA peak | 50 |
| 7 | Rated short circuit making capacity ima | kA peak | 50 |
| 8 | Rated mainly load breaking current capacity cosΦ=0.7 | A rms | 630 |
| 9 | Max Mainly active load breaking capacity cosΦ=0.7 | A rms | 630 |
| 10 | Rated closed breaking capacity cos Φ=0.3 | A rms | 630 |
| 11 | Rated single breaking capacity | A rms | 630 |
| 12 | Rated cable charging capacity | A rms | 50 |
| 13 | Power frequency withstand voltage 50Hz 1 min | kA rms kA rms | 55 65 |
| 14 | To earth Interphase/insulating voltage peak | kV peak kV peak | 145 125 |
| 15 | Mechanical life | 2500 operation | |
| 16 | Mac.operating torque when Closing Opening | N.M. N.M. | 64 64 |
| 17 | Operating angle on the shaft | Degree | 80 |
| 18 | Operating time | Ms | 35 |
| 19 | Arc-extinguish time | Ms | 20 |
| 20 | Earthing switch attachment Rated short-time current Peak withstand current Short circuit making capacity Power frequency withstand voltage (Lighting )impulse resisting voltage Pole distance | kA rms kA peak kA peak kV kV Mm | 25 50 50 55 125 275 |